Active cut sheets
Storefront, curtain wall, and thermal entrance data sheets with air-water-structural notes.
Specification sheets, installation guides, CAD drawings, color charts, and engineering data organized for architects, facade consultants, and contractors detailing storefront entrances, curtain wall, and thermal aluminum systems.
Storefront, curtain wall, and thermal entrance data sheets with air-water-structural notes.
Frame setting sequences, sill pan details, and weatherstrip replacement instructions including Series 14000 notes.
Typical head-jamb-sill conditions, mullion splices, and hardware prep drawings for project models.
Anodize and PVDF color chart references for architect finish boards and mock-up coupons.
System overview covering storefront doors, curtain wall, thermal entrances, and accessory hardware families.
Class I/II anodize and 70% PVDF options for matching Tubelite color chart samples to project boards.
Closer sizing, pivot selection, and weatherstrip kits coordinated to leaf weight and cycle expectations.
Field sequence notes for framing set, glazing, and final hardware adjustment on Series 14000 assemblies.
Specification writers compare mullion depths, thermal break classes, and NFRC U-factor / SHGC values against the basis of design.
Contractors attach cut sheets, color chart references, AAMA notes, and—where required—Miami-Dade NOA pathways for inspector review.
CAD details and finish coupons calibrate shop fabrication and field mock-ups before full elevation release.
Installation guides drive sill pan checks, sealant joint sequencing, and door hardware commissioning before turnover.
Resource packets flag where thermally broken entrances improve envelope U-factor yet change closer sizing relative to non-thermal leaves, and where stick curtain wall spans need deeper mullions that alter interior reveal conditions. When projects chase narrow sightlines and high design wind pressure at once, we publish system limits rather than implying one storefront family covers every coastal elevation. Prefabricated door leaf assemblies gain from factory hardware prep, but custom monumental openings still require project-specific pivot and panic coordination—our CAD notes call that handoff out instead of assuming catalog hardware always fits.
Typical data tables include design wind pressure, air infiltration rates, water penetration results, whole-system U-factor and SHGC, finish warranty classes, and hardware part numbers for pivots and weatherstrip. We also list air permeability, thermal bridging notes, UV stability for PVDF versus anodize, abrasion resistance expectations for high-cycle hardware, recycled content percentage, embodied carbon references, and service life expectancy ranges tied to finish class. Impact resistance pathways for Miami-Dade assemblies are packaged separately from inland AAMA results. Fire resistance rating interface notes appear when elevations meet rated walls. Request the Tubelite catalog when you need side-by-side comparisons of storefront versus curtain wall framing for mixed podium and tower packages, including wind load rating (PSF) tables for the jurisdiction on the permit set.
Tell us your building type, jurisdiction, and whether you need cut sheets, CAD, color charts, or installation guides. We assemble a Tubelite technical pack matched to storefront, curtain wall, or thermal entrance scope.